Transient thermal calculations

Learn about the limits of average power, transient thermal impedance, and repetitive duty cycles under pulsed loads.

<svg aria-label="Transient thermal calculations — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><path d="M115 37v145h425"></path><path d="M135 98h45V50h65v48h65V50h65v48h65V50h65v48"></path><path d="M135 168q42 0 56-15t40-12q30 10 54 2t35-10q30 10 53 1t35-9q30 10 95-6" stroke="#ba653d"></path><text class="kb-label" x="320" y="226">Power pulses · temperature over time</text></g></svg>

Temperature does not reach a steady state immediately

When a power pulse begins, the junction, package, and heatsink heat up at different rates. It is impossible to understand the junction peak that occurs in a short time by looking only at the external temperature of a large heatsink. While a thick base heats up slowly, a small semiconductor region can react much faster. Testing and calculations must represent the relevant time scale.

The difference between Rθ and Zθ

Steady-state thermal resistance Rθ represents the long-term temperature difference. Transient thermal impedance Zθ(t) describes the temperature response for a specific duration and boundary condition. Check whether the curve in the datasheet is for the junction-to-case path or another path. Using a normalized curve as an actual °C/W value will lead to incorrect results.

Annotated example for a single pulse

Assume the manufacturer provides ZθJC(10 ms)=0.2 °C/W under relevant conditions and that the case temperature remains approximately constant during this short time. The contribution of a 50 W constant power pulse to the junction-to-case temperature difference is approximately 50×0.2=10 °C. This increase is added to the initial case temperature. Example values are hypothetical; they cannot be transferred to a different package or duration.

The starting point changes with repetitive pulses

If the system does not cool down completely between pulses, the next pulse starts from a higher temperature. Average power is useful for evaluating long-term heatsink load; it does not determine the junction peak on its own. Use the pulse duration, period, power level, and initial temperature together. The manufacturer's repetitive pulse curves or an appropriate thermal network help evaluate the accumulation over time.

Share the duty cycle when selecting samples

The phrase "100 W occasionally" is not sufficient for thermal sizing. Specify how many milliseconds the pulse lasts and how often it repeats. When selecting an aluminum profile sample from Arma, you can prepare this load timeline along with the mounting dimensions. In addition to the peak junction temperature, also evaluate the base temperature that occurs during long cycles and the mechanical effects of thermal cycling.

Quick checklist

Frequently asked questions

Is a small heatsink sufficient if the average power is low?

That alone is not enough to decide. The semiconductor's short-term junction temperature limit and repetitive heating must also be checked.