Thermal grease or thermal pads
Evaluate your choice of thermal paste and pads based on gap, thickness, contact resistance, electrical insulation, and mounting pressure.
<svg aria-label="Thermal grease or thermal pads — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#deebee" height="40" rx="5" width="270" x="185" y="59"></rect><rect fill="#fbe8dd" height="12" rx="2" stroke="#ba653d" width="270" x="185" y="111"></rect><rect fill="#deebee" height="32" rx="4" width="320" x="160" y="137"></rect><path d="M230 31v16m90-16v16m90-16v16M230 177v20m90-20v20m90-20v20"></path><text class="kb-label" x="320" y="226">Contact surface · interface material · heatsink</text></g></svg>
The role of interface material
Although component and heatsink surfaces may appear smooth, they contain microscopic gaps. Thermal interface material is used to improve heat transfer within these gaps. The goal is not to apply as much material as possible between the surfaces, but to create a suitable and repeatable contact for the application.
When should you consider paste?
A thin layer of paste may be suitable for surfaces that are close together and mechanically compressed. The amount applied, surface cleanliness, and mounting pressure are critical. Filling large mechanical gaps with standard thermal paste is not a sound design approach. Electrical properties and behavior during temperature cycling should be verified against the product datasheet.
When should you consider pads?
Pads should be considered when you need controlled thickness, ease of assembly, or electrical insulation. A soft gap-filling pad and a thin insulating layer are not in the same product category. The compression ratio and applied force affect both thermal contact and the mechanical load on the component. Choosing a pad that is thicker than necessary to meet tolerances can result in a thermal penalty.
Do not compare only by W/(m·K)
In an ideal one-dimensional approach, material resistance is calculated as R=t/(k×A). For example, for a thickness of 0.5 mm, a conductivity of 3 W/(m·K), and an area of 20×20 mm, R is calculated as approximately 0.417 °C/W. If the thickness is 1 mm, it becomes 0.833 °C/W under the same assumptions. This example does not include contact resistance, spreading, or compression; for actual interface performance, the manufacturer's test method and assembly conditions are required.
Insulation and assembly must be designed together
In designs requiring electrical insulation, operating voltage, dielectric strength, creepage distances, and screw/bushing layout must be examined together. The fact that the center of a pad is insulating does not eliminate the electrical connection that a screw might create. Select the assembly torque according to the limits set by the component and interface manufacturer.
How to conduct a comparison test?
Compare two assemblies using the same component, heatsink, power, and environment. Standardize surface preparation and tightening methods. In addition to the initial test, evaluate behavior after temperature cycling or reassembly as required by the application. Do not make layer changes, such as adding a pad on top of paste, without justification; every additional layer introduces new contact surfaces.
Frequently asked questions
Is the product with the highest conductivity value the best?
Not always. Thickness, contact, compression, and mechanical suitability determine the overall result.
Does thermal paste provide electrical insulation?
It depends on the product; it should not be assumed without verifying the datasheet and application requirements.