Categories and filtersHomeProductsBack to category

Heatsinks

Shared heatsink calculations

Evaluate the total power, local base temperature, and individual junction temperature of each component on the common heatsink.

<svg aria-label="Shared heatsink calculations — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><path d="M175 120h290v12H175z"></path><path d="M185 120v-55M230 120v-55M275 120v-55M320 120v-55M365 120v-55M410 120v-55M455 120v-55"></path><rect fill="#fbe8dd" height="40" rx="5" width="65" x="208" y="146"></rect><rect fill="#fbe8dd" height="40" rx="5" width="65" x="366" y="146"></rect><path d="M240 146v-20m158 20v-20M260 135h105m-10-6 10 6-10 6" stroke="#ba653d"></path><text class="kb-label" x="320" y="226">Two heat sources · shared base</text></g></svg>

Common base, common heating

Components connected to the same heatsink are not independent of one another. When one heats up, the base used by the others may also heat up. Calculating for a single component by simply multiplying its own loss by the heatsink-to-air resistance ignores the contribution of other sources. First, determine the total power and operating durations of all sources operating simultaneously.

A simplified initial model

Assuming the base temperature is approximately uniform, we can write Ts≈Ta+Ptotal×RθSA. For each element, Tj,i≈Ts+Pi×(RθJC,i+RθCS,i) is calculated. This is a preliminary assessment model; it should be expanded if there is spreading resistance at the base or other significant heat paths. It should also be verified that the RθJC definition corresponds to the mounting surface used and that the interface data is consistent with the actual pressure.

Calculation example with two sources

Hypothetically, let the ambient temperature be 40 °C, the losses 10 W and 15 W, and the heatsink resistance 1.5 °C/W. The approximate base temperature becomes 40+25×1.5=77.5 °C. If the sum of the case and interface resistance for the first element is 1 °C/W, the junction is estimated at 87.5 °C; if the total for the second element is 0.8 °C/W, it is estimated at 89.5 °C. These are not product performance figures but numbers demonstrating how the model is used.

Examine the distance between sources

A wide base is not at a uniform temperature under all conditions. The proximity of sources to each other, their distance to the edge, and their position relative to the fins can alter the temperature distribution. Arma’s various base and fin geometries help generate alternatives for layout studies. When selecting candidates, place the hole pattern and the contact dimensions of the sources on the same drawing; do not establish equivalence based solely on profile width.

Separate electrical and thermal commonality

Using a common heatsink mechanically does not mean that all metal tabs can be connected electrically. Insulation requirements must be examined for each element. In the prototype, measure the base near each component separately. Tests where elements operate together and individually allow you to observe thermal interaction and understand where the simple model falls short.

Quick checklist

Frequently asked questions

Will two components on the same base have the same temperature?

Not necessarily. Their individual losses, package resistances, interfaces, and local base temperatures may differ.

Review relevant profiles · Request technical support