Categories and filtersHomeProductsBack to category

Heatsinks

Reading heatsink catalogue data

Compare heatsink candidates by accurately interpreting the K/W values, temperature rise curves, and airflow conditions in the catalog.

<svg aria-label="Reading heatsink catalogue data — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#fff" height="165" rx="4" width="230" x="205" y="30"></rect><path d="M230 65h85m-85 15h125M240 165v-65m0 65h165M250 112q55 48 140 35"></path><path d="M280 153v-21m0 0h46" stroke="#ba653d"></path><path d="M370 54h40m-40 14h40"></path><text class="kb-label" x="320" y="228">Curve · measurement conditions · operating point</text></g></svg>

Identify the two endpoints of the K/W value

Thermal resistance is the ratio of the temperature difference between two specific points to the power transferred. You may encounter a base-to-ambient value in a heatsink catalog; junction-to-case or junction-to-ambient values in a semiconductor datasheet describe different paths. Using the same unit does not make these values interchangeable. First, determine where the temperatures are measured and which heat path is covered.

Do not confuse natural and forced convection

The curve provided for a fanless condition and the curve for a specific airflow velocity represent different operating points. Boyd’s profile catalog illustrates how thermal data should be evaluated based on temperature difference and airflow velocity conditions. Do not directly equate the airflow velocity in the catalog with the fan's free-air delivery. The resistance created by the enclosure, ducting, and the heatsink itself alters the actual flow.

Read the geometry and layout conditions

Note details such as profile length, fin orientation, the location of the heat source on the base, and the finish. Do not assume that resistance is inversely proportional to length for a longer version of the same cross-section. If the manufacturer provides a curve or a correction method, use it. When the source area is very small, the spreading effect at the base may differ from catalog tests performed on a larger surface.

Test the operating point with a simple example

Let the verified base-to-ambient resistance for a hypothetical candidate under application conditions be 2 K/W, and the power transferred to the heatsink be 15 W. The expected base temperature rise would be approximately 30 K. If the air at the heatsink inlet is 40 °C, the base temperature is calculated to be approximately 70 °C. This result is not the junction temperature; temperature differences within the component and across the interface must be added separately.

Make missing conditions visible instead of guessing

Do not assume thermal performance is finalized if a catalog entry contains only dimensions and a product code. When selecting a mechanically suitable sample from among stock profiles, consolidate the cross-section, length, hole pattern, and actual operating conditions into a single note. Clarify missing thermal conditions with the supplier or verify them through application testing. This ensures the product code is evaluated alongside an agreed-upon test condition.

Quick checklist

Frequently asked questions

Is a product with a lower K/W rating in the catalog definitely better?

This ranking is only meaningful when measurement and operating conditions are comparable. Do not directly compare values provided under different air velocities or dimensions.