Power supply cooling
Learn the steps for selecting heatsinks for switching elements, rectifiers, and internal airflow in power supplies.
<svg aria-label="Power supply cooling — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#deebee" height="105" rx="5" width="170" x="235" y="65"></rect><path d="M115 117q15-35 30 0t30 0M175 117h60M405 105h90m-90 25h90M268 145l45-55-8 30h35l-38 30"></path><path d="M285 62V32m35 30V32m35 30V32" stroke="#ba653d"></path><text class="kb-label" x="320" y="226">Power conversion · electrical losses · heat</text></g></svg>
Rated power is not the heat the heatsink must dissipate
A power supply outputting 300 W does not mean the heatsink must dissipate 300 W. The thermal load is the electrical loss. This loss is distributed across transistors, rectifiers, magnetic components, and other parts. First, determine how much heat each component generates under the worst-case input voltage, output load, and operating mode.
Examine different points on the efficiency map
Seeing high efficiency at nominal load does not mean the entire operating range is suitable. Increased current at low input voltage or different switching behavior can change the loss distribution. Separate standby, light load, full load, and short-term overload conditions. Instead of applying a single efficiency percentage to all conditions, create a loss table using measurements or manufacturer models.
Define primary and secondary connections
The metal tab in contact with the heatsink may be electrically active. When connecting components at different potentials to a common profile, insulation, bushings, and mechanical layout must be evaluated together. Thermal paste alone does not provide a safe electrical isolation assumption. The electrical design lead must determine the application's relevant safety requirements; the thermal calculation must include the actual interface resistance of this assembly.
Protect the lifespan of neighboring components as well
While the heatsink temperature may be acceptable, nearby electrolytic capacitors can remain in hotter air. Arrange airflow so that heat-sensitive parts are not unnecessarily placed behind the hot zone. When choosing between Arma's component heatsinks and profile options, show the volume of not only the power element but also the surrounding parts in the mechanical drawing.
Establish an operating matrix for the prototype
Determine representative test points for input voltage, load, and ambient temperature. Collect data from the component, the heatsink base, and critical parts in the immediate vicinity. In fan-cooled systems, maintain filters and airflow direction. Do not rank results solely based on the lowest temperature; margins against tolerances, assembly repeatability, and maintenance requirements should also be part of the sampling decision.
Quick checklist
- Distribute losses among components.
- Prepare a test matrix for voltage, load, and environment.
- Check insulation and nearby component temperatures.
Frequently asked questions
Can I attribute the total loss to a single heatsink?
Only if it is verified that this heat is actually transferred to that heatsink. Components with separate thermal paths are evaluated individually.