A thermal design guide that addresses continuous load, acceleration, braking, and power module mounting in motor drives.
<svg aria-label="Motor drive cooling — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#deebee" height="110" rx="5" width="180" x="145" y="55"></rect><circle cx="445" cy="110" r="50"></circle><path d="M325 92h67m-67 20h67m-67 20h67M165 145V75h140M190 75v55m40-55v55m40-55v55M423 130V90l22 24 22-24v40"></path><path d="M145 183h180v12H145z"></path><path d="M155 183v-55M181.67 183v-55M208.33 183v-55M235 183v-55M261.67 183v-55M288.33 183v-55M315 183v-55"></path><text class="kb-label" x="320" y="226">Drive bridge · motor · cooling</text></g></svg>
Separate motor power from drive losses
The mechanical output power of the motor does not directly indicate the cooling requirements of the drive. Semiconductor conduction and switching losses depend on current, voltage, temperature, and operating mode. Losses in the DC link and other components also heat the enclosure. For your initial draft, create a simple thermal path diagram showing which heat flows from which component to which surface.
Extract the duty cycle from the actual application
Continuous constant load, frequent acceleration, and stop-start applications do not exhibit the same thermal behavior. Although acceleration current is short-lived, its repetition is significant. Energy generated during braking and the placement of external braking resistors, if present, must be addressed separately. For testing, define a cycle that represents not just the nominal current, but the variation of current and load over time.
Maintain base contact for the module
The wide base of a power module may not sit with uniform pressure at every point. Surface flatness, interface material, screw sequence, and the manufacturer's torque specifications all affect contact resistance. Do not use a universal tightening torque. Mounting that warps the base or stresses the module casing can negate the benefits of a well-designed heatsink geometry.
Look for hot spots on shared heatsinks
Mounting multiple switching elements on the same profile creates layout problems as well as total heat issues. Measure multiple points on the base to find the hottest region. Arma’s heatsink family for high-power applications can be reviewed for mechanical pre-selection; however, suitability for a specific drive must be verified based on that drive's losses and mounting requirements.
Include protection behavior in your test plan
Predefine how the system will behave if fan speed decreases or air intake becomes obstructed. The position of the temperature sensor affects the delay between the base temperature it measures and the semiconductor junction. In addition to steady-state testing, apply repetitive load cycles. Temperature limits and protection decisions should be determined in conjunction with relevant component data and system requirements.
Quick checklist
- Record the actual load cycle.
- Match module mounting to manufacturer instructions.
- Measure base distribution and protection scenarios.
Frequently asked questions
Does a single base sensor represent all elements?
Not always. Due to local hot spots and transient temperature differences, the sensor location must be verified through testing.