Categories and filtersHomeProductsBack to category

Heatsinks

How to choose a heatsink

Learn how to select a heatsink for your electronic circuit step-by-step, covering power loss, ambient temperature, thermal resistance, mounting, and prototype testing.

<svg aria-label="How to choose a heatsink — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#deebee" height="14" rx="2" width="220" x="210" y="174"></rect><rect fill="#f7fafb" height="76" rx="2" width="8" x="210" y="98"></rect><rect fill="#f7fafb" height="76" rx="2" width="8" x="240.29" y="98"></rect><rect fill="#f7fafb" height="76" rx="2" width="8" x="270.57" y="98"></rect><rect fill="#f7fafb" height="76" rx="2" width="8" x="300.86" y="98"></rect><rect fill="#f7fafb" height="76" rx="2" width="8" x="331.14" y="98"></rect><rect fill="#f7fafb" height="76" rx="2" width="8" x="361.43" y="98"></rect><rect fill="#f7fafb" height="76" rx="2" width="8" x="391.71" y="98"></rect><rect fill="#f7fafb" height="76" rx="2" width="8" x="422" y="98"></rect><rect fill="#fbe8dd" height="24" rx="4" stroke="#ba653d" width="60" x="290" y="188"></rect><path d="M265 90L265 46" stroke="#26798a"></path><path d="M259 54L265 46L271 54"></path><path d="M320 90L320 35" stroke="#26798a"></path><path d="M314 43L320 35L326 43"></path><path d="M375 90L375 46" stroke="#26798a"></path><path d="M369 54L375 46L381 54"></path><text class="kb-label" x="320" y="235">Heat source → heatsink → air</text></g></svg>

Start with operating conditions before dimensions

The suitability of a heatsink cannot be determined solely by its width or weight. The same profile will yield different results in an open environment versus a closed enclosure. First, determine the heat generated by the component, the temperature of the air reaching the heatsink, and the maximum allowable component temperature. This allows you to define the performance you need when searching for a product.

1. Distinguish between electrical power and power loss

The load the heatsink must dissipate is not the output power of the circuit, but the power lost as heat. For example, a converter delivering 100 W with 90% efficiency at a given operating point has a total loss of approximately 100 × (1/0.90 − 1) = 11.1 W. This loss does not occur entirely in a single transistor; the distribution between the semiconductor, inductor, and other components must be determined separately.

2. Establish a temperature budget

Do not automatically assume room temperature for the ambient environment. The air inside the cabinet, the power supply next to it, and the temperature at the fan intake may be higher. Instead of using the absolute maximum junction temperature from the datasheet as your normal operating target, choose a lower design target that aligns with the application's lifespan and reliability expectations.

3. Calculate the required thermal resistance

In a single-source, steady-state approach where heat primarily transfers from the case to the heatsink, the formula RθSA ≤ (Tj,target − Ta)/P − RθJC − RθCS is used. Assuming, purely for the sake of example, P=20 W, Ta=40 °C, Tj,target=110 °C, RθJC=1 °C/W, and RθCS=0.5 °C/W, the upper limit for the heatsink comes out to 2 °C/W. This is not an endorsement of any catalog product. If there is significant heat flow through the PCB or multiple heat sources, the model must be expanded.

4. Match catalog conditions with your design

Along with a °C/W value, you also need the profile length, airflow velocity, orientation, surface finish, and test conditions. Do not use a value provided for forced convection in a natural convection design. The mounting surface, holes, electrical insulation, and the height of adjacent components also determine the product's feasibility.

5. Validate the sample in the actual layout

Test the initial sample in a layout close to the final enclosure, using the actual interface material and mounting method. Record the starting temperature, load, ambient conditions, and temperatures over time. Once a steady state is reached, evaluate both the component and heatsink values. Comparing different samples under the same test conditions is far more meaningful than making decisions based on touch alone.

Information to prepare for sample selection

Gather the component code, continuous and peak power loss, target temperature, ambient range, available width-length-height, fan status, insulation requirements, and quantity needed. If the power loss is not yet known, state this; do not present results based on assumptions as measured values.

Frequently asked questions

Is a larger heatsink always sufficient?

No. If the transfer of heat to the base or the dissipation of heat out of the enclosure is restricted, simply increasing the size may not solve the problem.

Can thermal performance be understood from a product image?

Visual inspection is useful for preliminary screening; however, thermal suitability requires operating conditions, technical data, and testing.

Review relevant profiles · Request technical support