Categories and filtersHomeProductsBack to category

Heatsinks

Electrical insulation of heatsinks

Evaluate the insulating pad, bushing, and metal tab connection in terms of both thermal resistance and mechanical assembly.

<svg aria-label="Electrical insulation of heatsinks — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#deebee" height="25" rx="5" width="230" x="160" y="135"></rect><rect fill="#deebee" height="36" rx="5" width="160" x="195" y="77"></rect><rect fill="#fbe8dd" height="9" rx="5" width="200" x="175" y="119"></rect><path d="M437 75l45-18 45 18v38q0 42-45 64-45-22-45-64zM466 103h32v28h-32zM473 103v-10a9 9 0 0 1 18 0v10"></path><text class="kb-label" x="320" y="226">Thermal contact · electrical isolation</text></g></svg>

Read the metal tab connection from the datasheet

The metal tab of a power component may be electrically connected to a node in the circuit. Do not assume it is safe or isolated based on the package's external appearance. Determine the tab potentials of components connected to the same heatsink separately. The connection of the heatsink to the chassis and accessible parts must also be included in the system's electrical design.

The pad alone may not cover the entire path

The insulator between the component and the heatsink does not automatically prevent conductive paths that may form around the screw and hole. Appropriate bushings, washers, and assembly geometry may be required. Overhang, burrs, or sharp surfaces can damage the insulator. The required level of insulation must be determined through competent electrical design assessment based on operating voltage and relevant product requirements.

Do not confuse thermal conductivity with electrical insulation

Just because a material conducts heat well does not mean it is electrically insulating. The properties of thermal pastes and pads vary by product. Read the thickness, pressure, dielectric strength, and temperature conditions in the datasheet together. Do not use a strength value provided under laboratory test conditions as a direct safety approval for the entire assembly.

Insulation adds to the thermal budget

When interface resistance increases, the component temperature can rise for the same power loss. Although a thinner material may seem beneficial thermally, mechanical tolerances or electrical requirements may not permit it. Evaluating the heatsink's mounting surface, pad size, and fasteners in the same drawing makes this trade-off visible. Do not treat insulation as an accessory added as an afterthought.

Verify both function and assembly on the sample

Check the placement and mechanical integrity of the insulator before thermal testing. Electrical verification must be performed using the methods required by the application and appropriate test equipment; no general test voltage is provided here. The design is expected to maintain its intended properties even after temperature cycling, disassembly-reassembly, and production tolerances. Record test results along with the material code and assembly revision.

Quick checklist

Frequently asked questions

Is an anodized surface considered sufficient for safety insulation on its own?

It should not be considered as such without design-specific validation. Coating integrity, holes, contact points, and product requirements must be evaluated separately.

View relevant profiles · Request technical support