Copper-diamond composites
Explore the heat dissipation capabilities and electrical behavior of copper-diamond composites, and learn how to integrate new product announcements into your designs.
<svg aria-label="Copper-diamond composites — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#fbe8dd" height="130" rx="4" width="310" x="165" y="55"></rect><path d="M210 92l18-23 18 23-18 23Z"></path><path d="M280 120l18-23 18 23-18 23Z"></path><path d="M350 92l18-23 18 23-18 23Z"></path><path d="M420 120l18-23 18 23-18 23Z"></path><path d="M150 120h-45m8-7-8 7 8 7M490 120h45m-8-7 8 7-8 7"></path><text class="kb-label" x="320" y="228">Copper and diamond phases · schematic composite section</text></g></svg>
The goal is for the two materials to work in tandem
Copper-diamond composites are structures that combine metal and diamond phases within the same thermal component. The objective is to meet high heat dissipation capacity alongside manufacturing and connectivity requirements. However, "copper-diamond" does not describe a single recipe. The phase ratio, internal structure, interfaces, and coating can vary. Therefore, the conductivity and mechanical properties of the product cannot be calculated solely from the names of the components.
Read the development at the product announcement level
In its announcement dated January 22, 2025, Element Six introduced its Cu-Diamond solution for advanced semiconductor packages. The announcement specifies a thermal conductivity of approximately 800 W/(m·K). This figure is the manufacturer's claim for that specific product; it is not a universal value for all copper-diamond composites, nor is it the temperature drop in your specific application. Sample size, current data sheets, and delivery terms must be confirmed separately.
Containing diamond does not provide electrical insulation
Do not assume a composite containing a metal phase is an insulator just because it contains diamond. Element Six also specifies the electrical conductivity of its announced solution. This distinction is particularly important in power electronics: the potential to which the spreader will be connected and the layer at which electrical isolation is provided, if necessary, must be clear in the design. The thermal superiority of a material does not automatically satisfy isolation requirements.
Distinguish between internal and external boundaries
The internal interfaces of the composite contribute to the effective conductivity of the material, while the connections of the part to the chip and the heatsink create additional thermal resistance. Using only the value of the composite plate overlooks these external interfaces. Thickness, surface treatment, connection area, and expansion compatibility must be defined. Design evaluation should also include the temperature differences occurring on both sides of the spreader.
Establish the rationale for a hybrid solution through measurement
A specialized spreader may be considered for areas with high local heat flux, while an aluminum fin structure may be considered for larger volumes. This is a design approach; it does not mean the products are directly compatible. First, identify the bottleneck of your current solution. Then, compare the composite's contribution to temperature, mass, connection complexity, and cost under the same conditions. Instead of choosing a new material solely for its novelty, tie it to a measurable goal.
Quick checklist
- Record the manufacturer's claim along with the product class and measurement conditions.
- Check the electrical conductivity and the isolation path.
- Compare a sample that includes the interfaces with your current solution.
Frequently asked questions
Does an 800 W/(m·K) value mean four times better cooling?
No. Material conductivity and the total thermal resistance of an assembly are different metrics; the contributions of air, geometry, and interfaces must be calculated separately.