Categories and filtersHomeProductsBack to category

Heatsinks

Cooling SiC and GaN devices

Evaluate loss distribution, package thermal paths, and high power density together in SiC and GaN designs.

<svg aria-label="Cooling SiC and GaN devices — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#deebee" height="87" rx="5" width="125" x="150" y="74"></rect><rect fill="#deebee" height="87" rx="5" width="125" x="362" y="74"></rect><path d="M160 60V46m25 14V46m25 14V46m25 14V46m137 14V46m25 14V46m25 14V46m25 14V46M283 125h18V91h27v34h26"></path><text fill="#26798a" font-size="27" stroke="none" text-anchor="middle" x="212" y="128">SiC</text><text fill="#26798a" font-size="27" stroke="none" text-anchor="middle" x="425" y="128">GaN</text><path d="M190 168v28m45-28v28m165-28v28m45-28v28" stroke="#ba653d"></path></g></svg>

Higher efficiency does not mean cooling is unnecessary

SiC and GaN-based power components can help reduce losses and enable more compact system designs. However, smaller volumes may require heat to be dissipated from a more confined area. While total losses decrease, localized hot spots can still persist. First, establish a loss calculation that aligns with the system's operating conditions.

Define switching conditions realistically

Frequency, current, voltage, driving conditions, and circuit parasitics all impact losses. Do not assume a fixed efficiency or temperature advantage based solely on the technology name. Examine the measurement conditions under which the manufacturer's data was obtained. Evaluating different load points and transient operating states separately clarifies the criteria for selecting a heatsink.

Trace the package's actual thermal path

In some packages, heat is dissipated through the top surface, while in others, it travels through the board or via different parallel paths. The package drawing and thermal application note are the starting inputs for mechanical layout. Do not simply apply the mounting habits of a previous transistor to a new package. The board, thermal vias, and contact surface must be treated as a single system.

Examine base spreading in small contact areas

Even if the total surface area of a large heatsink appears sufficient, heat spreading from a small source to the base can create additional temperature differentials. Base thickness, source location, and the application quality of the interface are critical here. When comparing Arma’s aluminum profile options, share not only the external dimensions but also the package contact area and mounting layout.

Conduct electrical and thermal validation in parallel

In fast-switching circuits, heatsink connection, insulation, and parasitic effects must be evaluated alongside the electrical design. During thermal testing, use the measurement method recommended by the package manufacturer; do not assume the visible surface temperature is the junction temperature. Compare loss estimates with measurements on the first prototype and re-verify both temperature and electrical behavior after any mechanical changes.

Quick checklist

Frequently asked questions

Can a smaller heatsink be used when using SiC or GaN?

It may be possible in some designs; the decision must be validated by measured losses, local heat density, and temperature limits.