Calculating heat loss from efficiency
Calculate heat loss from input power, output power, and efficiency; learn how to distribute the result to the correct component and heatsink.
<svg aria-label="Calculating heat loss from efficiency — schematic technical drawing" class="kb-diagram" role="img" viewbox="0 0 640 250" xmlns="http://www.w3.org/2000/svg"><rect fill="#f3f7f8" height="250" rx="10" width="640"></rect><g fill="none" stroke="#26798a" stroke-linecap="round" stroke-linejoin="round" stroke-width="2.4"><rect fill="#deebee" height="95" rx="5" width="135" x="245" y="70"></rect><path d="M120 118h125m-13-8 13 8-13 8M380 105h137m-13-8 13 8-13 8"></path><path d="M380 140h55v43m-7-10 7 10 7-10" stroke="#ba653d"></path><text fill="#26798a" font-size="45" stroke="none" text-anchor="middle" x="312" y="133">η</text><text class="kb-label" x="320" y="226">Input power = output power + losses</text></g></svg>
Define the system boundary
Efficiency is the ratio of useful output power to input power within the chosen system boundary. Clearly define whether you are calculating for the power supply, the entire device, or a single converter stage. Including or excluding fans and auxiliary supplies within this boundary will change the result. Input and output measurements must correspond to the same operating point and time interval.
If output power is known
When efficiency η is used in decimal form, Pin=Pout/η, and total loss is Ploss=Pout×(1/η−1). For a hypothetical 200 W output and 92% efficiency, the input is approximately 217.4 W, and the loss is 17.4 W. Multiplying the output power directly by 8% yields 16 W, which calculates a different value; the denominator for efficiency is the input power.
If input power is known
In this case, Ploss=Pin×(1−η) can be used. For example, assuming 250 W input and 90% efficiency, the output is 225 W, and the total loss is 25 W. For AC input, you must measure the actual active power; simply multiplying RMS voltage by RMS current may not be sufficient due to the power factor. The bandwidth of the measuring device and the proper connection setup affect the result.
Loss is not concentrated in a single component
A result such as 17.4 W is the total loss within the device. Transistors, diodes, magnetic components, and resistors each account for different shares. Include only the heat transferred to the relevant thermal path in your heatsink calculation. Comparing dimensions between heatsink profiles only becomes meaningful after this loss distribution is determined. Follow the sequence of power budgeting, followed by mechanical pre-selection and prototype testing.
Measurement uncertainty of small differences
In high-efficiency systems, loss is the small difference between two large power values. The margin of error of the input and output devices can be significant for this difference. Do not confuse measurement resolution with actual accuracy. Use the value at the relevant load, input voltage, and temperature in your calculation instead of typical efficiency; update your initial assumptions with prototype measurement results.
Quick checklist
- Enter efficiency into the formula as a decimal, not a percentage.
- Synchronize input and output measurements at the same point.
- Distribute total loss across thermal paths.
Frequently asked questions
Is a 95% efficiency always a 5% loss of the output?
No. Efficiency is defined based on input power. If the output is known, use Pout×(1/0.95−1).